Technician
- Runs the test at the stack
- Sees every calculation as soon as the values are in
- Submits the finished job
Kemurix walks your technicians through each stack emission test, does the calculations on the spot, and sends the finished job to your lab. It keeps working with no signal at the site.
The app takes the technician through the test one phase at a time, and works out each result as soon as the values are in.
The technician picks a sampling time from 10 to 60 minutes. The phone rings for each reading, even when it is locked and offline.
The technician enters the stack height, diameter and port hole height. The app checks the 8D and 2D rule, then gives the number of traverse points and how far into the stack each one is.
| Point | Distance cm |
|---|---|
| 1 | 1.32 |
| 2 | 4.20 |
| 3 | 7.76 |
| 4 | 12.92 |
| 5 | 27.08 |
| 6 | 32.24 |
| 7 | 35.80 |
| 8 | 38.68 |
Up to 0.30 m: 4 points · up to 0.60 m: 8 points · above: 12 points
The technician works at the stack. The lab reads the results on the web.
The whole test runs on the phone. No network is needed until it is time to send the job.
Each value is saved the moment it is typed. If the phone switches off, the job opens again at the same phase.
When the phone finds a network, the finished job goes to the lab automatically, complete or not at all.
Each lab sees only its own jobs and people. Accounts are set up by your lab, never by public sign-up.